# speedtest-hd
A robust, CrystalDiskMarkstyle storage benchmark for Linux, built on [`fio`](https://fio.readthedocs.io/) by mReschke and my buddy Claude Opus.
It runs the same four tests CrystalDiskMark does, plus a dedicated **SLOG / syncwrite latency profile** for diagnosing ZFS ZIL performance (NFS / iSCSI / VM sync workloads). It autodetects the best IO engine and whether `O_DIRECT` works on the target, and falls back to a basic `dd` test when `fio` isn't installed.
---
## Table of contents
- [Features](#features)
- [Requirements](#requirements)
- [Usage](#usage)
- [Output](#output)
- [Understanding the tests](#understanding-the-tests)
- [Case study: diagnosing a "slow" Optane SLOG on TrueNAS](#case-study-diagnosing-a-slow-optane-slog-on-truenas)
- [Notes & caveats](#notes--caveats)
---
## Features
- **CrystalDiskMarkstyle profile** — `SEQ1M Q8T1`, `SEQ1M Q1T1`, `RND4K Q32T1`, `RND4K Q32T16`, each measured for Read **and** Write, reported in both **MB/s** and **IOPS**.
- **SLOG / syncwrite latency profile** (`--slog`) — synchronous 4K writes at T1/T4/T8/T16 reporting **IOPS, MB/s, and p50/p99 commit latency**. This is the load a ZFS SLOG actually sees.
- **Autodetection** — picks the fastest available IO engine (`io_uring``libaio``posixaio``sync`) and probes whether `O_DIRECT` works on the filesystem, falling back to buffered IO when it doesn't (e.g. older OpenZFS, some NFS mounts).
- **`dd` fallback** — if `fio` isn't present, runs a basic write/read test so you still get a number.
- **Verbose mode** — `--verbose` dumps the full raw `fio` output for every run while keeping the summary table intact.
---
## Requirements
- `bash`
- [`fio`](https://fio.readthedocs.io/) — recommended (`apt install fio` / `pacman -S fio`). Without it, the tool falls back to `dd`.
- `python3`**only** required for `--slog` (used to parse `fio`'s JSON output for latency percentiles). The normal profile needs only `fio` + `grep`/`awk`.
- `sudo``fio` is invoked via `sudo` so it can use `O_DIRECT` and flush device caches.
---
## Usage
```bash
./speedtest-hd.sh <path> [options]
```
`<path>` is the directory (or mount) to benchmark. Use `.` for the current directory. The tool creates a single test file (default 1 GiB) on the target and removes it afterward, so ensure enough free space.
### Modes
| Invocation | What it does |
|---|---|
| `./speedtest-hd.sh /mnt/disk` | Auto: uses `fio` if installed, else `dd` |
| `./speedtest-hd.sh /mnt/disk --fio` | Force the `fio` CrystalDiskMarkstyle profile |
| `./speedtest-hd.sh /mnt/disk --dd` | Force the basic `dd` test |
| `./speedtest-hd.sh /mnt/disk --slog` | SLOG / syncwrite latency profile |
### Tuning flags
| Flag | Effect |
|---|---|
| `--engine=io_uring\|libaio\|posixaio\|sync` | Force a specific IO engine (default: auto) |
| `--direct` | Force `O_DIRECT` (bypass page cache) |
| `--buffered` | Force buffered IO (e.g. when `O_DIRECT` is unsupported) |
| `--runtime=SEC` | Seconds per run (default: 5, like CrystalDiskMark) |
| `--size=SIZE` | Test file size (default: `1g`) |
| `--verbose` | Also print the full `fio` output for every run (summary table unchanged) |
### Examples
```bash
# CrystalDiskMark-style test of the current directory
./speedtest-hd.sh .
# Larger file, longer runs, on an NVMe pool
./speedtest-hd.sh /mnt/nvmepool --runtime=10 --size=4g
# Buffered (e.g. an NFS share that doesn't support O_DIRECT)
./speedtest-hd.sh /mnt/nfsshare --buffered
# SLOG / sync latency profile, 30s per run
./speedtest-hd.sh /mnt/nvme-ultra-r10/vm-root --slog --runtime=30
```
> **Tip:** when running `--slog` against a ZFS dataset, watch the SLOG live in another shell:
> ```bash
> zpool iostat -vl <pool> 1
> ```
---
## Output
### CrystalDiskMarkstyle profile
```
+------------------+----------------+----------------+----------------+----------------+
| Test | Read (MB/s) | Write (MB/s) | Read (IOPS) | Write (IOPS) |
+------------------+----------------+----------------+----------------+----------------+
| SEQ1M Q8T1 | 6873.00 | 9.30 | 6873 | 9 |
| SEQ1M Q1T1 | 1608.00 | 20.00 | 1608 | 20 |
| RND4K Q32T1 | 538.00 | 10.80 | 137728 | 2764 |
| RND4K Q32T16 | 689.00 | 261.00 | 176384 | 66816 |
+------------------+----------------+----------------+----------------+----------------+
```
### SLOG / syncwrite latency profile (`--slog`)
```
+------------------+--------------+--------------+--------------+--------------+
| Test | IOPS | MB/s | p50 lat(us) | p99 lat(us) |
+------------------+--------------+--------------+--------------+--------------+
| 4K sync T1 | 10687 | 43.77 | 85.5 | 185.3 |
| 4K sync T4 | 29873 | 122.36 | 117.8 | 317.4 |
| 4K sync T8 | 52612 | 215.50 | 136.2 | 391.2 |
| 4K sync T16 | 77939 | 319.24 | 180.0 | 505.9 |
+------------------+--------------+--------------+--------------+--------------+
```
---
## Understanding the tests
### The CrystalDiskMark profile
| Test | Pattern | Queue depth | Threads |
|---|---|---|---|
| `SEQ1M Q8T1` | Sequential 1 MiB | 8 | 1 |
| `SEQ1M Q1T1` | Sequential 1 MiB | 1 | 1 |
| `RND4K Q32T1` | Random 4 KiB | 32 | 1 |
| `RND4K Q32T16` | Random 4 KiB | 32 | 16 |
`Q` = queue depth (`--iodepth`), `T` = threads (`--numjobs`). Note that `--iodepth` only produces real queue depth when the IO is truly asynchronous (async engine **and** `O_DIRECT`). On filesystems where that isn't available, queue depth effectively collapses toward 1 and concurrency comes only from threads (`T`).
### The SLOG profile
`--slog` forces **synchronous** 4K random writes (`--sync=1``O_SYNC`) via the portable `psync` engine. Every write becomes a durable commit, so it traverses the ZFS ZIL / SLOG commit path exactly the way a `sync=always` dataset (NFS, iSCSI, VM storage) does — regardless of the dataset's own `sync` property. It sweeps thread counts (T1 → T4 → T8 → T16):
- **T1** is the headline singlestream latency (e.g. one database committing in a tight loop).
- **The sweep** shows how the SLOG scales as concurrent sync writers pile on (multiple VMs / NFS clients) — usually the more important number for a virtualization host.
A healthy Optane SLOG (e.g. P1600X) singlestream target is roughly **1525k IOPS, p50 ~4065 µs**. Much higher latency usually points at **CPU Cstates / PCIe ASPM / a BIOS power profile** throttling the host — see the case study below.
---
## Case study: diagnosing a "slow" Optane SLOG on TrueNAS
A real investigation that this tool's `--slog` mode was built to support. **Spoiler: the Optane SSD was healthy the entire time. The bottleneck was CPU power management.**
### The setup
| Component | Detail |
|---|---|
| Server | Dell PowerEdge R630 |
| CPU | Intel Xeon E52680 v3 (HaswellEP, 12C/24T, 2.5 GHz base, 3.3 GHz turbo) |
| OS | TrueNAS SCALE 25.10 (OpenZFS 2.3) |
| Pool | `nvme-ultra-r10` — 6× 4 TB KingSpec XG7000 NVMe in RAID10 (3 mirror vdevs) |
| SLOG | Intel Optane **P1600X** |
| Dataset | `/mnt/nvme-ultra-r10/vm-root`, `sync=always` |
### The symptom
The standard benchmark looked alarming — huge reads, tiny writes:
```
+------------------+------------------+------------------+
| Test | Read (MB/s) | Write (MB/s) |
+------------------+------------------+------------------+
| SEQ1M Q8T1 | 6873.00 | 9.30 |
| SEQ1M Q1T1 | 1608.00 | 20.00 |
| RND4K Q32T1 | 538.00 | 10.80 |
| RND4K Q32T16 | 689.00 | 261.00 |
+------------------+------------------+------------------+
```
9.3 MB/s sequential write on an Optanebacked NVMe pool looks broken.
### Investigation
**1. The reads are RAM, not disk.** With a 1 GiB test file on ZFS, reads come straight from ARC (RAM cache). The huge read/write asymmetry is the tell — ignore the read column for judging the disks.
**2. `sync=always` makes writes latencybound.** Every write must be durably committed to the ZIL before it's acknowledged, so throughput ≈ (block size) ÷ (percommit latency). Anything running at low effective concurrency looks slow regardless of raw device speed.
**3. The `Q8`/`Q32` labels were misleading.** On this ZFS setup `--iodepth` didn't produce real queue depth, so most rows effectively ran at QD1. Proof: `RND4K Q32T1` (10.8 MB/s) vs `RND4K Q32T16` (261 MB/s) — the 24× jump came entirely from threads (`numjobs=16`), not queue depth.
**4. Large sequential sync writes bypass the SLOG.** With ZFS's default `logbias=latency`, writes larger than `zfs_immediate_write_sz` (32 KB) use an *indirect* ZIL record — the data goes straight to the main pool and only a pointer hits the Optane. So the `SEQ1M` write test was measuring the **consumer KingSpec pool's** forcedsync performance, not the SLOG. Only small (4K) sync writes exercise the Optane.
**5. Confirm with `zpool iostat -vl <pool> 1` during a 4K sync test.** This was decisive:
- The `logs` (Optane) vdev took **all** the sync writes (~2.32.6k ops, ~1820 MB/s); the data vdevs were idle between txg flushes. → **SLOG configured correctly, `logbias` fine, not bypassed.**
- But the Optane's own `disk_wait` was **~90 µs** (a P1600X should be ~1015 µs), and the fiolevel commit latency was **~328 µs** — meaning ~238 µs was being spent *above* the device, in the host/ZFS/CPU path.
That "faster when busy, slow when idle" device latency plus huge host overhead is the classic signature of **powersaving idle states** on a latencybound, QD1 workload.
**6. Find the throttle.** Checking the CPU revealed the cores pinned at **1.2 GHz** — the E52680 v3's *minimum* Pstate — on a chip rated for 2.53.3 GHz:
```
$ grep MHz /proc/cpuinfo | sort -u
cpu MHz : 1200.069
...
$ cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_driver
intel_cpufreq # = intel_pstate in passive mode
$ cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_governor
schedutil # picks frequency from CPU utilization
```
The vicious loop: a QD1 sync workload spends each commit **blocked** waiting on the SLOG → the `schedutil` governor sees nearzero utilization → parks the cores at 1.2 GHz → the ZFS commit code path runs ~23× slower → latency climbs.
### Root cause
**CPU power management, in two layers — not the SSD, pool, or PCIe link:**
1. **BIOS System Profile = "Performance Per Watt Optimized (DAPC)"** — Dell Active Power Controller manages Cstates/Pstates in firmware and largely ignores the OS, keeping cores idling deep and clocked low.
2. **OS `schedutil` governor** (TrueNAS SCALE default) — pinned cores at the 1.2 GHz floor for this bursty, IOblocked workload.
### The fixes
Applied in order, biggest impact last:
**1. BIOS System Profile → Performance** (disables Cstates/C1E, raises Pstates):
```
# In BIOS (F2): System BIOS → System Profile Settings → System Profile → Performance
# Or via iDRAC:
racadm set BIOS.SysProfileSettings.SysProfile PerfOptimized
racadm jobqueue create BIOS.Setup.1-1
# reboot to apply
```
**2. Kernel parameters** (target PCIe/NVMe link power saving + residual Cstates). On TrueNAS: *System → Advanced Settings → Kernel Arguments*, then reboot:
```
intel_idle.max_cstate=1 processor.max_cstate=1 pcie_aspm=off nvme_core.default_ps_max_latency_us=0
```
**3. CPU governor → `performance`** *(the single biggest win)*:
```bash
echo performance | tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
```
Make it persistent on TrueNAS — *System → Advanced Settings → Init/Shutdown Scripts*, add a **Post Init** *Command*:
```
echo performance | tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
```
> ⚠️ Without the Post Init script the governor reverts to `schedutil` on every reboot, silently dropping you back to slow numbers.
### Results — before & after
**4K synchronous random writes** (`--slog`), per stage of the fix:
| Stage | T1 IOPS | T1 p50 | T1 MB/s | T16 IOPS | T16 MB/s | T16 p99 |
|---|---|---|---|---|---|---|
| **DAPC** (start) | ~3,050 | ~328 µs | ~12.5 | — | 38 *(regressing)* | thrashing |
| BIOS → Performance | 5,849 | 160.8 µs | 23.96 | 46,009 | 188.45 | 1057 µs |
| + kernel parameters | 6,217 | 150.5 µs | 25.46 | 47,166 | 193.19 | 684 µs |
| **+ `performance` governor** | **10,687** | **85.5 µs** | **43.77** | **77,939** | **319.24** | **506 µs** |
**Full final result:**
```
+------------------+--------------+--------------+--------------+--------------+
| Test | IOPS | MB/s | p50 lat(us) | p99 lat(us) |
+------------------+--------------+--------------+--------------+--------------+
| 4K sync T1 | 10687 | 43.77 | 85.5 | 185.3 |
| 4K sync T4 | 29873 | 122.36 | 117.8 | 317.4 |
| 4K sync T8 | 52612 | 215.50 | 136.2 | 391.2 |
| 4K sync T16 | 77939 | 319.24 | 180.0 | 505.9 |
+------------------+--------------+--------------+--------------+--------------+
```
**Net improvement:** ~**3.5× IOPS**, ~**3.8× lower latency** at T1, and ~**8.4× aggregate throughput** at T16 — with the scaling regression eliminated entirely.
### Lessons learned
- **An Optane SLOG showing high latency is usually a hostside powermanagement problem, not the device.** Confirm where the time goes before blaming hardware.
- **`zpool iostat -vl <pool> 1` is the key diagnostic** — it shows whether the `logs` vdev is actually taking the writes and splits device latency (`disk_wait`) from host/ZFS overhead (`total_wait`).
- **Latencybound QD1 sync workloads are the worst case for power saving.** The CPU looks idle (blocked on IO), so governors and firmware clock it down — which directly inflates the latency you're trying to measure.
- **On TrueNAS SCALE, the default `schedutil` governor cripples syncwrite latency.** Set `performance` (and persist it).
- **Reads from a small test file measure ARC (RAM), not the disk.** Watch the read/write asymmetry.
- **Large sync writes bypass the SLOG** (indirect ZIL) — to actually test a SLOG, use small (4K) sync writes, which is exactly what `--slog` does.
### `~85 µs` is roughly the floor here
The residual gap from raw Optane (~15 µs) is ZFS ZILcommit overhead plus the perop cost of a 2014era Haswell core. Closing it further would need a newer/faster CPU for sharply diminishing returns. For a virtualization host the aggregate (78k IOPS / 319 MB/s) is what the workload feels, and it's healthy.
---
## Notes & caveats
- **`sudo`** is used for `fio` so it can apply `O_DIRECT` and flush device write caches at the end of write runs (`--end_fsync=1`), so cached writes can't inflate results.
- **`O_DIRECT` is autodetected.** If the banner shows `O_DIRECT: DISABLED (buffered ...)`, results may reflect the page cache (RAM) rather than the device.
- **A single shared test file** is reused across runs to keep the footprint to one file.
- **`--slog` requires `python3`** (for JSON latencypercentile parsing); the standard profile does not.
- The `--slog` profile forces synchronous IO and is intended for ZFS ZIL / SLOG and other syncwrite (NFS/iSCSI/VM) investigations.