# speedtest-hd
|
||
|
||
A robust, CrystalDiskMark‑style storage benchmark for Linux, built on [`fio`](https://fio.readthedocs.io/) by mReschke and my buddy Claude Opus.
|
||
|
||
It runs the same four tests CrystalDiskMark does, plus a dedicated **SLOG / sync‑write latency profile** for diagnosing ZFS ZIL performance (NFS / iSCSI / VM sync workloads). It auto‑detects the best IO engine and whether `O_DIRECT` works on the target, and falls back to a basic `dd` test when `fio` isn't installed.
|
||
|
||
---
|
||
|
||
## Table of contents
|
||
|
||
- [Features](#features)
|
||
- [Requirements](#requirements)
|
||
- [Usage](#usage)
|
||
- [Output](#output)
|
||
- [Understanding the tests](#understanding-the-tests)
|
||
- [Case study: diagnosing a "slow" Optane SLOG on TrueNAS](#case-study-diagnosing-a-slow-optane-slog-on-truenas)
|
||
- [Notes & caveats](#notes--caveats)
|
||
|
||
---
|
||
|
||
## Features
|
||
|
||
- **CrystalDiskMark‑style profile** — `SEQ1M Q8T1`, `SEQ1M Q1T1`, `RND4K Q32T16`, `RND4K Q1T1` (CrystalDiskMark's default profile), each measured for Read **and** Write, reported in both **MB/s** and **IOPS**.
|
||
- **SLOG / sync‑write latency profile** (`--slog`) — synchronous 4K writes at T1/T4/T8/T16 reporting **IOPS, MB/s, and p50/p99 commit latency**. This is the load a ZFS SLOG actually sees.
|
||
- **Auto‑detection** — picks the fastest available IO engine (`io_uring` → `libaio` → `posixaio` → `sync`) and probes whether `O_DIRECT` works on the filesystem, falling back to buffered IO when it doesn't (e.g. older OpenZFS, some NFS mounts).
|
||
- **`dd` fallback** — if `fio` isn't present, runs a basic write/read test so you still get a number.
|
||
- **Verbose mode** — `--verbose` dumps the full raw `fio` output for every run while keeping the summary table intact.
|
||
|
||
---
|
||
|
||
## Requirements
|
||
|
||
- `python3` (3.7+) — the tool itself. It parses `fio`'s JSON output using only the standard library (no third‑party packages to install).
|
||
- [`fio`](https://fio.readthedocs.io/) — recommended (`apt install fio` / `pacman -S fio`). Without it, the tool falls back to a basic `dd` test.
|
||
- `sudo` — `fio` is invoked via `sudo` so it can use `O_DIRECT` and flush device caches.
|
||
|
||
---
|
||
|
||
## Usage
|
||
|
||
```bash
|
||
./speedtest-hd.py <path> [options]
|
||
# or: python3 speedtest-hd.py <path> [options]
|
||
```
|
||
|
||
`<path>` is the directory (or mount) to benchmark. Use `.` for the current directory. The tool creates a single test file (default 1 GiB) on the target and removes it afterward, so ensure enough free space.
|
||
|
||
### Modes
|
||
|
||
| Invocation | What it does |
|
||
|---|---|
|
||
| `./speedtest-hd.py /mnt/disk` | Auto: uses `fio` if installed, else `dd` |
|
||
| `./speedtest-hd.py /mnt/disk --fio` | Force the `fio` CrystalDiskMark‑style profile |
|
||
| `./speedtest-hd.py /mnt/disk --dd` | Force the basic `dd` test |
|
||
| `./speedtest-hd.py /mnt/disk --slog` | SLOG / sync‑write latency profile |
|
||
|
||
`--fio`, `--dd`, and `--slog` are mutually exclusive.
|
||
|
||
### Tuning flags
|
||
|
||
| Flag | Effect |
|
||
|---|---|
|
||
| `--engine {io_uring,libaio,posixaio,sync}` | Force a specific IO engine (default: auto) |
|
||
| `--direct` | Force `O_DIRECT` (bypass page cache) |
|
||
| `--buffered` | Force buffered IO (e.g. when `O_DIRECT` is unsupported) |
|
||
| `--runtime SEC` | Seconds per run (default: 5, like CrystalDiskMark) |
|
||
| `--size SIZE` | Test file size (default: `1g`) |
|
||
| `--verbose` | Also print the full `fio` output for every run (summary table unchanged) |
|
||
| `-y`, `--yes` | Skip the confirmation prompt (for scripting/automation) |
|
||
|
||
> All flags accept either `--flag value` or `--flag=value` (argparse). `--direct`/`--buffered` are mutually exclusive.
|
||
|
||
### Examples
|
||
|
||
```bash
|
||
# CrystalDiskMark-style test of the current directory
|
||
./speedtest-hd.py .
|
||
|
||
# Larger file, longer runs, on an NVMe pool
|
||
./speedtest-hd.py /mnt/nvmepool --runtime=10 --size=4g
|
||
|
||
# Buffered (e.g. an NFS share that doesn't support O_DIRECT)
|
||
./speedtest-hd.py /mnt/nfsshare --buffered
|
||
|
||
# SLOG / sync latency profile, 30s per run
|
||
./speedtest-hd.py /mnt/nvme-ultra-r10/vm-root --slog --runtime=30
|
||
|
||
# Unattended (no prompt), forcing a specific engine
|
||
./speedtest-hd.py /mnt/nvmepool --yes --engine io_uring
|
||
```
|
||
|
||
> **Tip:** when running `--slog` against a ZFS dataset, watch the SLOG live in another shell:
|
||
> ```bash
|
||
> zpool iostat -vl <pool> 1
|
||
> ```
|
||
|
||
---
|
||
|
||
## Output
|
||
|
||
### CrystalDiskMark‑style profile
|
||
|
||
Representative output from a healthy local NVMe (your numbers will differ):
|
||
|
||
```
|
||
+------------------+----------------+----------------+----------------+----------------+
|
||
| Test | Read (MB/s) | Write (MB/s) | Read (IOPS) | Write (IOPS) |
|
||
+------------------+----------------+----------------+----------------+----------------+
|
||
| SEQ1M Q8T1 | 3650.00 | 3120.00 | 3482 | 2976 |
|
||
| SEQ1M Q1T1 | 2680.00 | 2510.00 | 2556 | 2394 |
|
||
| RND4K Q32T16 | 2950.00 | 2240.00 | 720215 | 546875 |
|
||
| RND4K Q1T1 | 78.00 | 64.00 | 19043 | 15625 |
|
||
+------------------+----------------+----------------+----------------+----------------+
|
||
```
|
||
|
||
### SLOG / sync‑write latency profile (`--slog`)
|
||
|
||
```
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
| Test | IOPS | MB/s | p50 lat(us) | p99 lat(us) |
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
| 4K sync T1 | 10687 | 43.77 | 85.5 | 185.3 |
|
||
| 4K sync T4 | 29873 | 122.36 | 117.8 | 317.4 |
|
||
| 4K sync T8 | 52612 | 215.50 | 136.2 | 391.2 |
|
||
| 4K sync T16 | 77939 | 319.24 | 180.0 | 505.9 |
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
```
|
||
|
||
---
|
||
|
||
## Understanding the tests
|
||
|
||
### The CrystalDiskMark profile
|
||
|
||
| Test | Pattern | Queue depth | Threads |
|
||
|---|---|---|---|
|
||
| `SEQ1M Q8T1` | Sequential 1 MiB | 8 | 1 |
|
||
| `SEQ1M Q1T1` | Sequential 1 MiB | 1 | 1 |
|
||
| `RND4K Q32T16` | Random 4 KiB | 32 | 16 |
|
||
| `RND4K Q1T1` | Random 4 KiB | 1 | 1 |
|
||
|
||
`Q` = queue depth (`--iodepth`), `T` = threads (`--numjobs`). Note that `--iodepth` only produces real queue depth when the IO is truly asynchronous (async engine **and** `O_DIRECT`). On filesystems where that isn't available, queue depth effectively collapses toward 1 and concurrency comes only from threads (`T`).
|
||
|
||
### The SLOG profile
|
||
|
||
`--slog` forces **synchronous** 4K random writes (`--sync=1` → `O_SYNC`) via the portable `psync` engine. Every write becomes a durable commit, so it traverses the ZFS ZIL / SLOG commit path exactly the way a `sync=always` dataset (NFS, iSCSI, VM storage) does — regardless of the dataset's own `sync` property. It sweeps thread counts (T1 → T4 → T8 → T16):
|
||
|
||
- **T1** is the headline single‑stream latency (e.g. one database committing in a tight loop).
|
||
- **The sweep** shows how the SLOG scales as concurrent sync writers pile on (multiple VMs / NFS clients) — usually the more important number for a virtualization host.
|
||
|
||
A healthy Optane SLOG (e.g. P1600X) single‑stream target is roughly **15–25k IOPS, p50 ~40–65 µs**. Much higher latency usually points at **CPU C‑states / PCIe ASPM / a BIOS power profile** throttling the host — see the case study below.
|
||
|
||
---
|
||
|
||
## Case study: diagnosing a "slow" Optane SLOG on TrueNAS
|
||
|
||
A real investigation that this tool's `--slog` mode was built to support. **Spoiler: the Optane SSD was healthy the entire time. The bottleneck was CPU power management.**
|
||
|
||
### The setup
|
||
|
||
| Component | Detail |
|
||
|---|---|
|
||
| Server | Dell PowerEdge R630 |
|
||
| CPU | Intel Xeon E5‑2680 v3 (Haswell‑EP, 12C/24T, 2.5 GHz base, 3.3 GHz turbo) |
|
||
| OS | TrueNAS SCALE 25.10 (OpenZFS 2.3) |
|
||
| Pool | `nvme-ultra-r10` — 6× 4 TB KingSpec XG7000 NVMe in RAID10 (3 mirror vdevs) |
|
||
| SLOG | Intel Optane **P1600X** |
|
||
| Dataset | `/mnt/nvme-ultra-r10/vm-root`, `sync=always` |
|
||
|
||
### The symptom
|
||
|
||
The standard benchmark looked alarming — huge reads, tiny writes:
|
||
|
||
```
|
||
+------------------+------------------+------------------+
|
||
| Test | Read (MB/s) | Write (MB/s) |
|
||
+------------------+------------------+------------------+
|
||
| SEQ1M Q8T1 | 6873.00 | 9.30 |
|
||
| SEQ1M Q1T1 | 1608.00 | 20.00 |
|
||
| RND4K Q32T1 | 538.00 | 10.80 |
|
||
| RND4K Q32T16 | 689.00 | 261.00 |
|
||
+------------------+------------------+------------------+
|
||
```
|
||
|
||
9.3 MB/s sequential write on an Optane‑backed NVMe pool looks broken.
|
||
|
||
> **Note:** this investigation was captured with an earlier test profile that used `RND4K Q32T1` in place of today's `RND4K Q1T1`. The `Q32T1` vs `Q32T16` comparison below is exactly why the default later changed — see finding #3.
|
||
|
||
### Investigation
|
||
|
||
**1. The reads are RAM, not disk.** With a 1 GiB test file on ZFS, reads come straight from ARC (RAM cache). The huge read/write asymmetry is the tell — ignore the read column for judging the disks.
|
||
|
||
**2. `sync=always` makes writes latency‑bound.** Every write must be durably committed to the ZIL before it's acknowledged, so throughput ≈ (block size) ÷ (per‑commit latency). Anything running at low effective concurrency looks slow regardless of raw device speed.
|
||
|
||
**3. The `Q8`/`Q32` labels were misleading.** On this ZFS setup `--iodepth` didn't produce real queue depth, so most rows effectively ran at QD1. Proof: `RND4K Q32T1` (10.8 MB/s) vs `RND4K Q32T16` (261 MB/s) — the 24× jump came entirely from threads (`numjobs=16`), not queue depth.
|
||
|
||
**4. Large sequential sync writes bypass the SLOG.** With ZFS's default `logbias=latency`, writes larger than `zfs_immediate_write_sz` (32 KB) use an *indirect* ZIL record — the data goes straight to the main pool and only a pointer hits the Optane. So the `SEQ1M` write test was measuring the **consumer KingSpec pool's** forced‑sync performance, not the SLOG. Only small (4K) sync writes exercise the Optane.
|
||
|
||
**5. Confirm with `zpool iostat -vl <pool> 1` during a 4K sync test.** This was decisive:
|
||
|
||
- The `logs` (Optane) vdev took **all** the sync writes (~2.3–2.6k ops, ~18–20 MB/s); the data vdevs were idle between txg flushes. → **SLOG configured correctly, `logbias` fine, not bypassed.**
|
||
- But the Optane's own `disk_wait` was **~90 µs** (a P1600X should be ~10–15 µs), and the fio‑level commit latency was **~328 µs** — meaning ~238 µs was being spent *above* the device, in the host/ZFS/CPU path.
|
||
|
||
That "faster when busy, slow when idle" device latency plus huge host overhead is the classic signature of **power‑saving idle states** on a latency‑bound, QD1 workload.
|
||
|
||
**6. Find the throttle.** Checking the CPU revealed the cores pinned at **1.2 GHz** — the E5‑2680 v3's *minimum* P‑state — on a chip rated for 2.5–3.3 GHz:
|
||
|
||
```
|
||
$ grep MHz /proc/cpuinfo | sort -u
|
||
cpu MHz : 1200.069
|
||
...
|
||
|
||
$ cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_driver
|
||
intel_cpufreq # = intel_pstate in passive mode
|
||
$ cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_governor
|
||
schedutil # picks frequency from CPU utilization
|
||
```
|
||
|
||
The vicious loop: a QD1 sync workload spends each commit **blocked** waiting on the SLOG → the `schedutil` governor sees near‑zero utilization → parks the cores at 1.2 GHz → the ZFS commit code path runs ~2–3× slower → latency climbs.
|
||
|
||
### Root cause
|
||
|
||
**CPU power management, in two layers — not the SSD, pool, or PCIe link:**
|
||
|
||
1. **BIOS System Profile = "Performance Per Watt Optimized (DAPC)"** — Dell Active Power Controller manages C‑states/P‑states in firmware and largely ignores the OS, keeping cores idling deep and clocked low.
|
||
2. **OS `schedutil` governor** (TrueNAS SCALE default) — pinned cores at the 1.2 GHz floor for this bursty, IO‑blocked workload.
|
||
|
||
### The fixes
|
||
|
||
Applied in order, biggest impact last:
|
||
|
||
**1. BIOS System Profile → Performance** (disables C‑states/C1E, raises P‑states):
|
||
```
|
||
# In BIOS (F2): System BIOS → System Profile Settings → System Profile → Performance
|
||
# Or via iDRAC:
|
||
racadm set BIOS.SysProfileSettings.SysProfile PerfOptimized
|
||
racadm jobqueue create BIOS.Setup.1-1
|
||
# reboot to apply
|
||
```
|
||
|
||
**2. Kernel parameters** (target PCIe/NVMe link power saving + residual C‑states). On TrueNAS: *System → Advanced Settings → Kernel Arguments*, then reboot:
|
||
```
|
||
intel_idle.max_cstate=1 processor.max_cstate=1 pcie_aspm=off nvme_core.default_ps_max_latency_us=0
|
||
```
|
||
|
||
**3. CPU governor → `performance`** *(the single biggest win)*:
|
||
```bash
|
||
echo performance | tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
|
||
```
|
||
Make it persistent on TrueNAS — *System → Advanced Settings → Init/Shutdown Scripts*, add a **Post Init** *Command*:
|
||
```
|
||
echo performance | tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
|
||
```
|
||
> ⚠️ Without the Post Init script the governor reverts to `schedutil` on every reboot, silently dropping you back to slow numbers.
|
||
|
||
### Results — before & after
|
||
|
||
**4K synchronous random writes** (`--slog`), per stage of the fix:
|
||
|
||
| Stage | T1 IOPS | T1 p50 | T1 MB/s | T16 IOPS | T16 MB/s | T16 p99 |
|
||
|---|---|---|---|---|---|---|
|
||
| **DAPC** (start) | ~3,050 | ~328 µs | ~12.5 | — | 38 *(regressing)* | thrashing |
|
||
| BIOS → Performance | 5,849 | 160.8 µs | 23.96 | 46,009 | 188.45 | 1057 µs |
|
||
| + kernel parameters | 6,217 | 150.5 µs | 25.46 | 47,166 | 193.19 | 684 µs |
|
||
| **+ `performance` governor** | **10,687** | **85.5 µs** | **43.77** | **77,939** | **319.24** | **506 µs** |
|
||
|
||
**Full final result:**
|
||
|
||
```
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
| Test | IOPS | MB/s | p50 lat(us) | p99 lat(us) |
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
| 4K sync T1 | 10687 | 43.77 | 85.5 | 185.3 |
|
||
| 4K sync T4 | 29873 | 122.36 | 117.8 | 317.4 |
|
||
| 4K sync T8 | 52612 | 215.50 | 136.2 | 391.2 |
|
||
| 4K sync T16 | 77939 | 319.24 | 180.0 | 505.9 |
|
||
+------------------+--------------+--------------+--------------+--------------+
|
||
```
|
||
|
||
**Net improvement:** ~**3.5× IOPS**, ~**3.8× lower latency** at T1, and ~**8.4× aggregate throughput** at T16 — with the scaling regression eliminated entirely.
|
||
|
||
### Lessons learned
|
||
|
||
- **An Optane SLOG showing high latency is usually a host‑side power‑management problem, not the device.** Confirm where the time goes before blaming hardware.
|
||
- **`zpool iostat -vl <pool> 1` is the key diagnostic** — it shows whether the `logs` vdev is actually taking the writes and splits device latency (`disk_wait`) from host/ZFS overhead (`total_wait`).
|
||
- **Latency‑bound QD1 sync workloads are the worst case for power saving.** The CPU looks idle (blocked on IO), so governors and firmware clock it down — which directly inflates the latency you're trying to measure.
|
||
- **On TrueNAS SCALE, the default `schedutil` governor cripples sync‑write latency.** Set `performance` (and persist it).
|
||
- **Reads from a small test file measure ARC (RAM), not the disk.** Watch the read/write asymmetry.
|
||
- **Large sync writes bypass the SLOG** (indirect ZIL) — to actually test a SLOG, use small (4K) sync writes, which is exactly what `--slog` does.
|
||
|
||
### `~85 µs` is roughly the floor here
|
||
|
||
The residual gap from raw Optane (~15 µs) is ZFS ZIL‑commit overhead plus the per‑op cost of a 2014‑era Haswell core. Closing it further would need a newer/faster CPU for sharply diminishing returns. For a virtualization host the aggregate (78k IOPS / 319 MB/s) is what the workload feels, and it's healthy.
|
||
|
||
---
|
||
|
||
## Notes & caveats
|
||
|
||
- **`sudo`** is used for `fio` so it can apply `O_DIRECT` and flush device write caches at the end of write runs (`--end_fsync=1`), so cached writes can't inflate results.
|
||
- **`O_DIRECT` is auto‑detected.** If the banner shows `O_DIRECT: DISABLED (buffered ...)`, results may reflect the page cache (RAM) rather than the device.
|
||
- **A single shared test file** is reused across runs to keep the footprint to one file.
|
||
- **All profiles parse `fio`'s JSON output** (`--output-format=json`) with Python's standard library — robust, unit‑safe metrics with no fragile text scraping.
|
||
- The `--slog` profile forces synchronous IO and is intended for ZFS ZIL / SLOG and other sync‑write (NFS/iSCSI/VM) investigations.
|